USFDA guidelines, GMP guidelines, WHO guidelines, Schedule M, FDA, European guidelines cleaning validation, process validation, water system validation, ICH guidelines, GMP audut compliance, equipment qualification, Installation Qualification, Operational Qualification, Performance Qualification, Calibration, Validation Protocol, SOPs etc.
Saturday, December 31, 2011
Assay of Ascorbic acid
Assay of Ascorbic acid
Reagents Required:
1.0M Sulfuric acid
0.05M Iodine
Procedure
Weigh accurately about 0.1gm of sample and dissolve in a mixture of 100 ml freshly boiled and cooled water and 25ml of 1M sulfuric acid. Immediately Titrate with 0.05M iodine, using starch solution as indicator until a persistent blue-violet color is obtained. Each ml of 0.05M iodine is equivalent to 0.008806gm of ascorbic acid.
Calculation:
BR X Actual molarity X 0.008806 X 100
% of Ascorbic acid = ----------------------------------------------------
0.05 X Wt. Of sample
BR= Burette Reading